Hydrophone Logger

Acoustic leak detection loggers

Description

ENIGMA® SMART, POWERFUL, AND BUILT TO LISTEN WHERE & when IT MATTERS MOST.

Enigma Hydrophone Logger is a variant of the standard Enigma multi-point correlation logger that has been further optimized for leak location in plastic and large diameter pipes over longer distances. A high sensitivity hydrophone is used (directly detects the pressure wave in the water) coupled with the application of narrow band filtering.

NARROW BAND FILTERING

FILTERINGThe Narrow Band Filter tool automatically ‘sweeps’ the frequency range and produces multiple correlations in different frequency band. The technique can enable results when operating over longer distances and large diameter mains.

MULTI-POINT CORRELATION

Enigma Hydrophone loggers are deployed during normal working hours at multiple insertion points along a main. Enigma-hyQ gives optimum performance by recording the leak sound at night – when background acoustic noise is lowest and water pressure is usually highest.
When retrieved the leak sound is transferred to the host software where it is processed to display leak positions.
Programming and data read-back utilizes optical and USB communications to ensure rapid operation

OPTIMUM DESIGN

For detecting quiet leaks Enigma is designed with the lowest possible ‘electronic noise floor’ – the lowest random noise generated within the logger’s semiconductors. This is coupled to the ability to process very low frequency signals.

Additional information

Sensor Type

Hydrophone (connected externally)

Sensor Frequency Range

1- 2400 Hz

Sensor Sensitivity

-195dB

Sensor Attachment

1” BSP connection + pipe adaptors

Sensor Material

Aluminium

Sensor Ingress Protection Rating

Submersible to IP68

Sensor Operating Temperature

-10°C to +60°C

Sensor Physical Dimensions

104mm (high) x 59mm (diameter)

Sensor Max Total Recording Time

180 seconds

Sensor Data Memory

32MB static RAM

Sensor Communications Type

Optical

Sensor Communications Rate

2.5 Mbits/sec

Sensor Power Type

Dual Lithium Cells

Sensor Battery Replacement

At factory or service center

Sensor Operating Time

>5 years (when standard programming used)

Number of Epochs

1, 2, or 3

Ephoc Duration

60 seconds

Sampling Rate

4860 Hz

Sampling Resolution

24-bit

Host Communication Type

USB

Data Saved Into Case

One run (8 correlations)

Power Supply Type

User replaceable alkaline 4 cell pack

Physical Dimmensions

8 logger: 410 x 325 x 172 mm 3 logger: 270 x 246 x 174 mm

Case Material

Ruggedised high impact plastic

Case Ingress Protection Rate

IP65

Case Operating Temperature

-10°C to +60°C