LC-2500

Compact & Lightweight Leak Correlator.

LC-2500

Compact & Lightweight Leak Correlator.

The Main Processor Unit, weighing less than 7 lb.,can easily be carried all day. 

The Main Processor Unit and the Pre-Amps/Transmitters can operate in rain storms, subzero temps., and direct sun for hours.

The new LC-2500 sensors are very sensitive, small in diameter, and totally submersible.

Runs all day on standard or rechargeable “D” batteries.

Input pipe materials, diameters, and lengths by simply selecting them in the program menus. The automatic functions can do the rest.

The Main Processor Unit displays the correlation “picture” and the distances to the leak from the Red pre-amp transmitter and the Blue pre-amp transmitter.

Key Features

  • Type: Piezoelectric pick-up 
  • Voltage Sensitivity: 2.5V/g (peak) 
  • Applicable Standard: IP68 (water-proof) 
  • Drop Resistance: 3 feet (asphalt) 
  • External Dimensions: 1.2 inches diameter x 5.1 inches high 
  • Weight: 15 ounces each 
  • Power Supply System: 3-wire 
  • Output Impedance: 100, max. 
  • Power Supply Voltage: 5.0V

TECHNICAL SPECIFICATIONS

Additional information

Main Processor Unit Operating Temperature Range

-10 to 50°C

Main Processor Unit External Dimensions

7.8 inches (W) x 4.0 inches (D) x 9.9 inches (H)

Main Processor Unit Weight

Approx. 6.8 lb. (with batteries)

Main Processor Unit Battery

4 "D" Cells (std or rechargeable)

Main Processor Unit Continuous Operating Time

3 hours minimum (at 20°C, backlight OFF)

Main Processor Unit Minimum Operating Voltage

4.2V

Main Processor Unit Input

Radio or Cable

Main Processor Unit Display

Dot matrix LCD

Main Processor Unit Operation

Polarity correlation

Main Processor Unit Td Range

50ms, 100ms, d200ms, 400ms, 800ms, 1600ms or automatic setting

Main Processor Unit Time Resolution

25 µs (in 50ms range), 50 µs (in 100ms range)
100 µs (in 200ms range), 200 µs (in 400ms range)
400 µs (in 800ms range), 800 µs (in 1600ms range)

Main Processor Unit Filter Range

THRU, 80Hz to 5,000Hz (4 low and 4 high)

Main Processor Unit Notch Filter

OFF, 50Hz, 60Hz

Main Processor Unit Auto Filter

Automatically selected from FFT operation

Main Processor Unit Data Memory

100 correlations

Main Processor Unit FFT Monitor

1kHz, 2.5kHz, 5kHz (common to both channels)

Main Processor Unit Sound Memory

For 16 seconds

Main Processor Unit External Interface

RS-232C

Red and Blue Pre-Amplifiers Operating Temperature Range

-10 to 50°C

Red and Blue Pre-Amplifiers Applicable Standard

IP52 (weather tight)

Red and Blue Pre-Amplifiers External Dimensions

5.9 inches (W) x 4.3 inches (D) x 14.5 inches (H)

Red and Blue Pre-Amplifiers Weight

Approx. 6.3 lb. (with batteries)

Red and Blue Pre-Amplifiers Battery

6 "D" Cells (std or rechargeable)

Red and Blue Pre-Amplifiers Continuous Operating Time

10 hours minimum (at 20ºC, backlight OFF)

Red and Blue Pre-Amplifiers Minimum Operating Time

6.0V

Red and Blue Pre-Amplifiers Input

Input Frequency Range:
20Hz to 5kHz (at THRU filter setting)
100Hz to 5KHz (at STD filter setting)

Input Sensitivity:
50 micro V, max.

Signal to Noise Ratio:
35dB, min.

Red and Blue Pre-Amplifiers Radio Communication System

Output Frequency:
UHF under approved freq.

Modulation:
Direct frequency modulation

Output Power:
0.5W (500mW)

Output Impedance:
50